      1-Material for sterile technique(only gloves and mask are necessary)

      2-Spinal Needle, 20 and 22-gauge

      3-Manometer

      4- Three-way stopcock

      5-Sterile drapes

      6-1% lidocaine without epinephrine in a 5-cc syringe with a 22 and 25-gauge needles

      7-Material for skin sterilizationn

      8- Adhesive dressing

      9- Sponges - 10 X 10 cm

      Technique

      1- Place the patient in the lateral decubitus position lying on the edge of the bed and facing away from operator. Place the patient in a knee-chest position with the neck flexed. The patient's head should rest on a pillow, so that the entire cranio-spinal axis is parallel to the bed. Sitting position is the second choice because there may be a greater risk of herniation and CSF pressure cannot be measured

      2- Find the posterior iliac crest and palpate the L4 spinous process, and mark the spot with a fingernail. Prepare the skin by starting at the puncture site and working outward in concentric circles. Put on sterile gloves. Drape the patient

      3- Anesthetize the skin using the 1% lidocaine in the 5 mL syringe with the 25-gauge needle. Change to 22-gauge needle before anesthetizing between the spinous process. Insert in the midline with the needle parallel to the floor and the point directed toward the patient's umbilicus

      4- Advance slowly about 2 cm or until a "pop'' (piercing a membrane of the dura) is heard. Then withdraw the stylet in every 2- to 3-mm advance of the needle to check for CSF return. If the needle meets the bone or if blood returns (hitting the venous plexus anterior to the spinal canal), withdraw to the skin and redirect the needle. If CSF return cannot be obtained, try one disk space down

      5- When cerebrospinal fluid begins to flow from the needle, discard the first few drops. Do not aspirated cerebrospinal fluid, because a nerve root may be trapped against the needle and injuried

      6- Measure the opening pressure with a manometer; allow the patient to relax, and check for good respiratory variation of the fluid level in the manometer to ensure that the needle is properly positioned.

      8- Remove the manometer and allow 1 to 2 cc of CSF to flow into each of the three sterile tubes. Send the first for glucose and protein, the second for Gram stain and culture and sensitivity (C&S), and the third for cell count and differential. A fourth tube, when indicated, is collected for viral titer or cultures, India ink preparation, Cryptococcus antigen, VDRL, or cytology

      9- Withdraw the needle without replacing the stylet

      10- Dress the puncture site with a bandage. Have the patient lie in bed for a few hours

      Complications

      A. Postlumbar puncture headache occurs in 10% to 30% of patients within 1 to 3 days and lasts 2 to 7 days. The pain is relieved by lying flat. Treatment consists of bed rest and fluid with simple analgesics.

      Bibliography

      1-Hayward RA, Shapiro MF, Oye RK: Laboratory testing on cerebrospinal fluid: A repappraisal. Lancet 1987;1:1-4.

      2-Marton KI, Gean AD,: The spinal tap: A new look at an old test. Annals of Internal Medicine 1986;104:840-48.

      3-Charles E. Saunders, Mary T. Ho(eds): In Current Emergency Diagnosis and Treatment. Fourth edition, 1992.

    分享到:

    发表评论】【加入收藏】【告诉好友】【打印此文】【关闭窗口
  • 上一篇文章:
  • 下一篇文章:
  • [护理英语]补充阅读:中风患者脑细胞死亡之  [护理英语]补充阅读:“效果预期”对治疗脑
    [护理英语]补充阅读:处理护士吸烟所造成的  [护理英语]补充阅读:低智商可增加年轻人的
    [护理英语]补充阅读:维生素E可预防化疗病人  [护理英语]补充阅读:脂肪激素可抑制肥胖症
    [护理英语]补充阅读:妊娠期间补充维C会增加  [护理英语]补充阅读:红肉与直结肠癌有关
    [护理英语]医学英语阅读:隔离MRSA病人并不  [护理英语]补充阅读:p53研究的新发现
关于我们 | 合作加盟 | 广告服务 | 联系我们 | 网站导航 | 我要投稿 | 最近更新 |网站管理| 加入收藏
有害短信息举报 | 360网站安全检测平台 | 版权所有 | QQ群: 208861788
Copyright © 2008 - 2022 pooson.cn Inc. All Rights Reserved
粤ICP备10006718号 版权声明:本网站为非营利性网站,部分资源来源其他网站,
如果有些资源侵犯你的版权,请及时联系我们,以便我们处理!站长QQ:(1107044562) 邮箱:pooson@qq.com互联网安全